Woodpex III Woodpecker apex locator

₦154,000.00
Tax excluded

Woodpex III Woodpecker channel meter for dentistry.

A apex locator is a support team in the treatment of endodontics, which is responsible for measuring the length of the apical region.

QTY:

Review:

Characteristics:

Equipped with an LCD screen with clear and color image to indicate the trajectory of the needle in a simple way.
Based on advanced multi-frequency impedance measurement technology and automatic calibration, to ensure accurate measurement.
     The "Woodpex III" accessories can be autoclaved at high temperature and high pressure to avoid cross infection effectively.
     The battery is rechargeable, there is no need to change it.
     The tester / tester allows to verify that the equipment works correctly:
     Demo function

Application:

This equipment is applied to perform the detailed measurements below:

     Measurement of pulpitis, pulp necrosis, periapical periodontitis and tooth length.
     Measurement of tooth length measurement before crown restoration.
     Measurement of the length of the teeth before transplants.

Technical specifications:

Battery: 3.7 V / 750 mAH
Adapter: ~ 100 V-240V 50Hz / 60Hz
Energy consumption: ≤0.5 W
Screen: LCD 4.5 "
Alarm: a buzzing sound will sound when the endodontic needle is less than 2 mm from the apex.
Operating conditions
Ambient temperature: +5 ~ - + 40ºC
Relative humidity: ≤80%.
Atmospheric pressure: 50kPa ~ 106kPa
Dimensions main unit: 13 x 9 x 10 cm.
Type of protection against electric shock: class II equipment
Degree of protection against electric shock: applied parts type BF
Water resistance: ordinary equipment (IPX0)

This equipment is not suitable for use in the presence of flammable anesthetic mixtures with air, oxygen or nitrous oxide: not suitable under these conditions.

Cleaning and sterilization:

The main unit and the measuring cable can be disinfected with alcohol and a disinfected cloth.
Do not use harsh chemicals or cleaning agents to clean the equipment. It could cause damage to the main unit and the measuring cable.
The needle holder, lip hook and measuring needle should be autoclaved at high pressure (0.22MPa) and high temperature (135ºC) before each operation.

It includes:

Main unit
Measuring cable
4 Needle holder
2 Lip hooks
2 measuring needles
Tester / tester
AC adapter
Battery
Manual

EML - WWA- 001
33 Items